Presentation,e-document

DANTUMA Maura, LUCKA Felix, TREEBY Bradley E., JAROŠ Jiří, COX Ben T. and MANOHAR Srirang. Signal Frequency Content and Appearance of Tumors in Photoacoustic Breast Tomography: A Simulation. Caparica, 2018.
Publication language:english
Original title:Signal Frequency Content and Appearance of Tumors in Photoacoustic Breast Tomography: A Simulation
Pages:1-1
Conference:3rd International Caparica Conference on Ultrasonic-based Applications: from analysis to synthesis
Place:Caparica, PT
Year:2018
Files: 
+Type Name Title Size Last modified
iconPoster_Ultrasonics2018_md2.pdfPoster11,4 MB2018-07-16 05:13:19
^ Select all
With selected:
Keywords
Photoacoustic imaging, Breast tomography, k-Wave
Annotation
Photoacoustic tomography (PAT) setups increasingly used in clinical studies. PA tumor appearance differs per system due to lack of standardization in technical system specifications. More information about tumor appearance required to improve image interpretation .This study investigates: PA frequency content of tumors with different vessel distributions: homogeneous (solid) and superficial (hollow). Their PA appearance with 0.5 and 1 MHz transducers.

Your IPv4 address: 18.234.51.17
Switch to https